GHS precautionary statement

P370+P380: In case of fire: Evacuate area

  • P370+P380
  • Response
  • Combined statement
  • Deleted

P370+P380 was the precautionary statement “In case of fire: Evacuate area”. It is marked as deleted in the GHS data we compile, so it is not part of the current GHS revision.

This code has been removed from GHS. You may still find it on older labels and SDSs. Our data does not say which code replaced it, so check the supplier's current SDS.

About the response group

P300 series: what to do after a spill, exposure or fire, including first-aid steps and when to call a poison center or doctor. See all precautionary statements for the full list.

Component statements

A combined statement joins single statements that are printed as one sentence. This one is made of:

CodeStatement
P370In case of fire:
P380Evacuate area.

Hazards that call for P370+P380

The GHS data recommends P370+P380 for these hazard statements.

CodeStatementHazard class and categorySignal word
H201Explosive; mass explosion hazard Deleted
Explosives — Div 1.1
Danger
H202Explosive; severe projection hazard Deleted
Explosives — Div 1.2
Danger
H203Explosive; fire, blast or projection hazard Deleted
Explosives — Div 1.3
Danger
H205May mass explode in fire Deleted
Explosives — Div 1.5
Danger

Related current statements

These current statements share part of their wording or code with P370+P380.

CodeStatement
P370In case of fire:
P380Evacuate area.
P370+P376in case of fire: Stop leak if safe to do so.
P370+P378In case of fire: Use ... to extinguish.
P370+P380+P375In case of fire: Evacuate area. Fight fire remotely due to the risk of explosion.
P371+P380+P375In case of major fire and large quantities: Evacuate area. Fight fire remotely due to the risk of explosion.
P370+P372+P380+P373In case of fire: Explosion risk. Evacuate area. DO NOT fight fire when fire reaches explosives.
P370+P380+P375[+P378]In case of fire: Evacuate area. Fight fire remotely due to the risk of explosion. [Use...to extinguish].]

Chemicals using P370+P380

No chemicals in our database list P370+P380 in their primary classification yet.

P370+P380 frequently asked questions

Is P370+P380 still used?

No. P370+P380 ("In case of fire: Evacuate area") is marked as deleted in the GHS data we compile, so it is not part of the current GHS revision. It may still appear on older labels and safety data sheets.

What did P370+P380 say?

"In case of fire: Evacuate area". It was a response precautionary statement.

Precautionary statements are general recommendations. Follow the specific instructions on your product's label and safety data sheet.

https://pubchem.ncbi.nlm.nih.gov/ghs/ghscode_10.txt (UN GHS Revision 10, retrieved 2026-10-12)